Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Beilstein J Org Chem ; 16: 1343-1356, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32595782

RESUMEN

Magnesium organometallic reagents occupy a central position in organic synthesis. The freshness of these compounds is the key for achieving a high conversion and reproducible results. Common methods for the synthesis of Grignard reagents from metallic magnesium present safety issues and exhibit a batch-to-batch variability. Tubular reactors of solid reagents combined with solution-phase reagents enable the continuous-flow preparation of organomagnesium reagents. The use of stratified packed-bed columns of magnesium metal and lithium chloride for the synthesis of highly concentrated turbo Grignards is reported. A low-cost pod-style synthesizer prototype, which incorporates single-use prepacked perfluorinated cartridges and bags of reagents for the automated on-demand lab-scale synthesis of carbon, nitrogen, and oxygen turbo magnesium bases is presented. This concept will provide access to fresh organomagnesium reagents on a discovery scale and will do so independent from the operator's experience in flow and/or organometallic chemistry.

2.
ACS Med Chem Lett ; 11(1): 9-15, 2020 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-31938456

RESUMEN

In-line purification is an important tool for flow chemistry. It enables effective handling of unstable intermediates and integration of multiple synthetic steps. The integrated flow synthesis is useful for drug synthesis and process development in medicinal chemistry. In this article, we overview current states of in-line purification methods. In particular, we focus on four common methods: scavenger column, distillation, nanofiltration, and extraction. Examples of their applications are provided.

3.
Molecules ; 24(2)2019 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-30669256

RESUMEN

The reliable and efficient production of radioisotopes for diagnosis and therapy is becoming an increasingly important capability, due to their demonstrated utility in Nuclear Medicine applications. Starting from the first processes involving the separation of 99mTc from irradiated materials, several methods and concepts have been developed to selectively extract the radioisotopes of interest. Even though the initial methods were based on liquid-liquid extraction (LLE) approaches, the perceived difficulty in automating such processes has slowly moved the focus towards resin separation methods, whose basic chemical principles are often similar to the LLE ones in terms of chelators and phases. However, the emerging field of flow chemistry allows LLE to be easily automated and operated in a continuous manner, resulting in an even improved efficiency and reliability. In this contribution, we will outline the fundamentals of LLE processes and their translation into flow-based apparatuses; in addition, we will provide examples of radioisotope separations that have been achieved using LLE methods. This article is intended to offer insights about the future potential of LLE to purify medically relevant radioisotopes.


Asunto(s)
Extracción Líquido-Líquido , Radioisótopos/aislamiento & purificación , Extracción Líquido-Líquido/instrumentación , Extracción Líquido-Líquido/métodos , Medicina Nuclear/instrumentación , Medicina Nuclear/métodos
4.
Science ; 361(6408): 1220-1225, 2018 09 21.
Artículo en Inglés | MEDLINE | ID: mdl-30237351

RESUMEN

Chemical synthesis generally requires labor-intensive, sometimes tedious trial-and-error optimization of reaction conditions. Here, we describe a plug-and-play, continuous-flow chemical synthesis system that mitigates this challenge with an integrated combination of hardware, software, and analytics. The system software controls the user-selected reagents and unit operations (reactors and separators), processes reaction analytics (high-performance liquid chromatography, mass spectrometry, vibrational spectroscopy), and conducts automated optimizations. The capabilities of this system are demonstrated in high-yielding implementations of C-C and C-N cross-coupling, olefination, reductive amination, nucleophilic aromatic substitution (SNAr), photoredox catalysis, and a multistep sequence. The graphical user interface enables users to initiate optimizations, monitor progress remotely, and analyze results. Subsequent users of an optimized procedure need only download an electronic file, comparable to a smartphone application, to implement the protocol on their own apparatus.

5.
Chemistry ; 24(11): 2776-2784, 2018 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-29385292

RESUMEN

As a demonstration of an alternative to the challenges faced with batch pharmaceutical manufacturing including the large production footprint and lengthy time-scale, we previously reported a refrigerator-sized continuous flow system for the on-demand production of essential medicines. Building on this technology, herein we report a second-generation, reconfigurable and 25 % smaller (by volume) continuous flow pharmaceutical manufacturing platform featuring advances in reaction and purification equipment. Consisting of two compact [0.7 (L)×0.5 (D)×1.3 m (H)] stand-alone units for synthesis and purification/formulation processes, the capabilities of this automated system are demonstrated with the synthesis of nicardipine hydrochloride and the production of concentrated liquid doses of ciprofloxacin hydrochloride, neostigmine methylsulfate and rufinamide that meet US Pharmacopeia standards.


Asunto(s)
Preparaciones Farmacéuticas/síntesis química , Automatización , Ciprofloxacina/síntesis química , Ciprofloxacina/aislamiento & purificación , Neostigmina/síntesis química , Neostigmina/aislamiento & purificación , Nicardipino/síntesis química , Nicardipino/aislamiento & purificación , Preparaciones Farmacéuticas/aislamiento & purificación , Triazoles/síntesis química , Triazoles/aislamiento & purificación
6.
Nat Chem Biol ; 13(5): 464-466, 2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-28244989

RESUMEN

Here we report a fully automated, flow-based approach to solid-phase polypeptide synthesis, with amide bond formation in 7 seconds and total synthesis times of 40 seconds per amino acid residue. Crude peptide purities and isolated yields were comparable to those for standard-batch solid-phase peptide synthesis. At full capacity, this approach can yield tens of thousands of individual 30-mer peptides per year.


Asunto(s)
Automatización/métodos , Péptidos/síntesis química , Péptidos/química
7.
Science ; 352(6281): 61-7, 2016 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-27034366

RESUMEN

Pharmaceutical manufacturing typically uses batch processing at multiple locations. Disadvantages of this approach include long production times and the potential for supply chain disruptions. As a preliminary demonstration of an alternative approach, we report here the continuous-flow synthesis and formulation of active pharmaceutical ingredients in a compact, reconfigurable manufacturing platform. Continuous end-to-end synthesis in the refrigerator-sized [1.0 meter (width) × 0.7 meter (length) × 1.8 meter (height)] system produces sufficient quantities per day to supply hundreds to thousands of oral or topical liquid doses of diphenhydramine hydrochloride, lidocaine hydrochloride, diazepam, and fluoxetine hydrochloride that meet U.S. Pharmacopeia standards. Underlying this flexible plug-and-play approach are substantial enabling advances in continuous-flow synthesis, complex multistep sequence telescoping, reaction engineering equipment, and real-time formulation.


Asunto(s)
Química Farmacéutica/métodos , Preparaciones Farmacéuticas/síntesis química , Diazepam/síntesis química , Diazepam/normas , Difenhidramina/síntesis química , Difenhidramina/normas , Lidocaína/síntesis química , Lidocaína/normas , Preparaciones Farmacéuticas/normas , Farmacopeas como Asunto
8.
Chembiochem ; 15(5): 713-20, 2014 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-24616230

RESUMEN

A flow-based solid-phase peptide synthesis methodology that enables the incorporation of an amino acid residue every 1.8 min under automatic control or every 3 min under manual control is described. This is accomplished by passing a stream of reagent through a heat exchanger into a low volume, low backpressure reaction vessel, and through a UV detector. These features enable continuous delivery of heated solvents and reagents to the solid support at high flow rate, thereby maintaining maximal concentration of reagents in the reaction vessel, quickly exchanging reagents, and eliminating the need to rapidly heat reagents after they have been added to the vessel. The UV detector enables continuous monitoring of the process. To demonstrate the broad applicability and reliability of this method, it was employed in the total synthesis of a small protein, as well as dozens of peptides. The quality of the material obtained with this method is comparable to that for traditional batch methods, and, in all cases, the desired material was readily purifiable by RP-HPLC. The application of this method to the synthesis of the 113-residue Bacillus amyloliquefaciens RNase and the 130-residue DARPin pE59 is described in the accompanying manuscript.


Asunto(s)
Péptidos/síntesis química , Técnicas de Síntesis en Fase Sólida/instrumentación , Secuencia de Aminoácidos , Diseño de Equipo , Datos de Secuencia Molecular , Péptidos/química , Técnicas de Síntesis en Fase Sólida/economía , Factores de Tiempo
9.
J Vis Exp ; (81): e50980, 2013 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-24300077

RESUMEN

Rapid mechanical deformation of cells has emerged as a promising, vector-free method for intracellular delivery of macromolecules and nanomaterials. This technology has shown potential in addressing previously challenging applications; including, delivery to primary immune cells, cell reprogramming, carbon nanotube, and quantum dot delivery. This vector-free microfluidic platform relies on mechanical disruption of the cell membrane to facilitate cytosolic delivery of the target material. Herein, we describe the detailed method of use for these microfluidic devices including, device assembly, cell preparation, and system operation. This delivery approach requires a brief optimization of device type and operating conditions for previously unreported applications. The provided instructions are generalizable to most cell types and delivery materials as this system does not require specialized buffers or chemical modification/conjugation steps. This work also provides recommendations on how to improve device performance and trouble-shoot potential issues related to clogging, low delivery efficiencies, and cell viability.


Asunto(s)
Técnicas Citológicas/instrumentación , Técnicas Citológicas/métodos , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Forma de la Célula , Sistemas de Liberación de Medicamentos , Células HeLa , Humanos , Sustancias Macromoleculares/administración & dosificación
10.
Proc Natl Acad Sci U S A ; 110(6): 2082-7, 2013 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-23341631

RESUMEN

Intracellular delivery of macromolecules is a challenge in research and therapeutic applications. Existing vector-based and physical methods have limitations, including their reliance on exogenous materials or electrical fields, which can lead to toxicity or off-target effects. We describe a microfluidic approach to delivery in which cells are mechanically deformed as they pass through a constriction 30-80% smaller than the cell diameter. The resulting controlled application of compression and shear forces results in the formation of transient holes that enable the diffusion of material from the surrounding buffer into the cytosol. The method has demonstrated the ability to deliver a range of material, such as carbon nanotubes, proteins, and siRNA, to 11 cell types, including embryonic stem cells and immune cells. When used for the delivery of transcription factors, the microfluidic devices produced a 10-fold improvement in colony formation relative to electroporation and cell-penetrating peptides. Indeed, its ability to deliver structurally diverse materials and its applicability to difficult-to-transfect primary cells indicate that this method could potentially enable many research and clinical applications.


Asunto(s)
Sistemas de Liberación de Medicamentos , Técnicas Analíticas Microfluídicas , Animales , Fenómenos Biomecánicos , Permeabilidad de la Membrana Celular , Forma de la Célula , Células Cultivadas , Citosol/metabolismo , Células Dendríticas/citología , Células Dendríticas/metabolismo , Difusión , Expresión Génica , Células HeLa , Humanos , Células Madre Pluripotentes Inducidas/citología , Células Madre Pluripotentes Inducidas/metabolismo , Ratones , Nanotubos de Carbono , Proteínas/administración & dosificación , ARN Interferente Pequeño/administración & dosificación
11.
Anal Chem ; 85(3): 1637-41, 2013 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-23259401

RESUMEN

We present a microfluidic electroporation device with a comb electrode layout fabricated in polydimethylsiloxane (PMDS) and glass. Characterization experiments with HeLa cells and fluorescent dextran show efficient delivery (∼95%) with low toxicity (cell viability ∼85%) as well as rapid pore closure after electroporation. The activity of delivered molecules is also verified by silencing RNA (siRNA) studies that demonstrate gene knockdown in GFP expressing cells. This simple, scalable approach to microfluidic, flow-through electroporation could facilitate the integration of electroporation modules within cell analysis devices that perform multiple operations.


Asunto(s)
Electroporación/métodos , Técnicas de Transferencia de Gen , Sustancias Macromoleculares/metabolismo , Amanitinas/administración & dosificación , Amanitinas/genética , Amanitinas/metabolismo , Electroporación/instrumentación , Técnicas de Transferencia de Gen/instrumentación , Células HeLa , Humanos , Sustancias Macromoleculares/administración & dosificación , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , ARN Interferente Pequeño/administración & dosificación , ARN Interferente Pequeño/genética , ARN Interferente Pequeño/metabolismo
12.
Nano Lett ; 12(12): 6322-7, 2012 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-23145796

RESUMEN

The ability to straightforwardly deliver engineered nanoparticles into the cell cytosol with high viability will vastly expand the range of biological applications. Nanoparticles could potentially be used as delivery vehicles or as fluorescent sensors to probe the cell. In particular, quantum dots (QDs) may be used to illuminate cytosolic proteins for long-term microscopy studies. Whereas recent advances have been successful in specifically labeling proteins with QDs on the cell membrane, cytosolic delivery of QDs into live cells has remained challenging. In this report, we demonstrate high throughput delivery of QDs into live cell cytoplasm using an uncomplicated microfluidic device while maintaining cell viabilities of 80-90%. We verify that the nanoparticle surface interacts with the cytosolic environment and that the QDs remain nonaggregated so that single QDs can be observed.


Asunto(s)
Citoplasma/metabolismo , Técnicas Analíticas Microfluídicas/instrumentación , Puntos Cuánticos/administración & dosificación , Supervivencia Celular , Sistemas de Liberación de Medicamentos/instrumentación , Endocitosis , Células HeLa , Humanos , Puntos Cuánticos/metabolismo
13.
Anal Chem ; 84(15): 6438-43, 2012 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-22746217

RESUMEN

Mechanical properties of cells have been shown to have a significant role in disease, as in many instances cell stiffness changes when a cell is no longer healthy. We present a high-throughput microfluidics-based approach that exploits the connection between travel time of a cell through a narrow passage and cell stiffness. The system resolves both cell travel time and relative cell diameter while retaining information on the cell level. We show that stiffer cells have longer transit times than less stiff ones and that cell size significantly influences travel times. Experiments with untreated HeLa cells and cells made compliant with latrunculin A and cytochalasin B further demonstrate that travel time is influenced by cell stiffness, with the compliant cells having faster transit time.


Asunto(s)
Microfluídica , Compuestos Bicíclicos Heterocíclicos con Puentes/toxicidad , Tamaño de la Célula/efectos de los fármacos , Citocalasina B/toxicidad , Electrodos , Células HeLa , Humanos , Microfluídica/instrumentación , Tiazolidinas/toxicidad
14.
Lab Chip ; 8(8): 1258-61, 2008 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-18651065

RESUMEN

We report a microfluidic based approach for single cell microinjection in which fluid streams direct a cell onto a fixed microneedle in contrast to moving a microneedle towards an immobilized cell, as done in conventional methods. The approach simplifies microinjection and offers the potential for flow through automated microinjection of cells.


Asunto(s)
Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Microfluídica/instrumentación , Microfluídica/métodos , Microinyecciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...